Installation Instructions
Model Number 1052-CCOAP
(877) 867-2312 www.oberonwireless.com
Rev. 2A 06/05/14 Oberon, Inc.
1315 South Allen Street
State College, PA 16801 Copyright 2013
Assembly Components:
- Ceiling enclosure Model 1052-CCOAP assembly – 1 each
- 1” Trade size conduit connectors – 1 each
- Firestop Grommet – 1 each
- #8 – 32 screw – 4 each
- #6 – 32 screw – 4 each
- Support wire – 4 each
- Installation Instructions – 1 each
- Keys for access door lock – 2 each
If any of these items are missing, contact your Oberon representative.
NOTE: If using Cisco 1040, 1140, 1260, 3500 series
access point use Cisco AIR-AP-BRACKET-2. If
using Cisco 3600 series use Cisco AIR-AP-
BRACKET-1.
Find a flat work surface to assemble the ceiling
enclosure, access point and antenna(s) prior to
mounting in ceiling.
Step 1 Place the ceiling enclosure assembly on the
work surface with the keyed doorway unlocked.
Remove hole knock outs located on the outside edge
of the back box to install conduit connectors. Install
one conduit connector if using P.O.E. or install 2
conduit connectors if bringing in power and Ethernet
and power separately (Figure 1).
Step 2 Install the mounting plate onto the mounting bracket using the
(4) # 8-32 screws. The triangle cutouts of the mounting plate should be
facing down toward the cutout on the bracket. Slide the access point onto
the mounting plate using the feet to lock it in place (Figure 2).
Page 2
Step 3 The door assembly is completed by attaching the
previously assembled mounting plate/access point
assembly to the enclosure door by securing it in place with
four (4) #8-32 hex nuts. Place the slotted holes in the
mounting plate/access point assembly over the studs
located on the bottom side of the door (NOTE: the
mounting plate can only be attached to the door in one
direction. If the slotted holes don’t match up with the studs
in the door, rotate the mounting plate 180°). Once the
mounting plate is positioned, secure it in place by installing
four (4) #8-32 hex nuts (Figure 3).
The assembled unit is now ready for ceiling installation.
Step 4 – Remove the ceiling tile and replace it with the completed access point enclosure assembly.
Step 5 Use minimum 12-gauge support wire (included) to support the access point enclosure independently of the ceiling
grid. Attach one end of the wire to the support wire tabs located along the edge of the back box and the other end to a
permanent supporting structure within the ceiling such as a ceiling joist (Figure 4).
**IMPORTANT** - This is an important safety feature that could prevent human injury or damage to the access
point should the unit become dislodged from the ceiling.