Installation Instructions
Model Number 1058-08-ANT5-F
(877) 867-2312 www.oberonwireless.com
Rev. A1 05/23/13 Oberon, Inc.
1315 South Allen Street
State College, PA 16801 Copyright 2013
Figure 1
Figure 2
Figure 3
Figure 4
Assembly Components:
- Enclosure Model 1058-08-ANT5-F assembly – 1 each
- 3/4” Trade size cable clamps – 1 each
- Fire Block Foam – 1 each
- hanger wire – 8 each
- Keys for access door lock – 1 each
- Installation Instructions – 1 each
- Stainless Steel Mounting Brackets and Hardware Kit – 4 each
- Internal universal equipment mounting plate – 1 each
If any of these items are missing, contact your Oberon representative.
Find a flat work surface to assemble the enclosure and any other network/cellular components prior to mounting in ceiling.
Step 1 Place the enclosure assembly back side down on the work surface and keyed doorway unlocked. Remove the internal mounting
plate if needed and the desired number of knockouts on the sides and door of the enclosure.
**IMPORTANT** - The brackets must be assembled in the order shown to maintain a watertight seal.
Step 2 Flip the enclosure to one of its sides. Remove the rubber hole plugs located on the under side of the enclosure. Attach the
mounting brackets (Figure 1) per the provided Assembly Instructions. Place the back side of the enclosure down on the work surface. If
previously removed, install the mounting plate again with its respective hardware.
**IMPORTANT** - Determine the correct access point installation method based on the manufacturer.
Step 3a (For Cisco AP’s Only) The mounting holes for Cisco AP’s are located in the mounting plate. Standard Cisco mounting brackets
as well as “Bracket 2” can be attached so the “Cisco” logo of the AP is parallel to the hinge. For “Bracket 1” the logo of the AP will be
mounted perpendicular to the hinge. Securely fasten the access point’s mounting plate to the mounting holes on the mounting plate of the
enclosure using four (4) # 8-32 self tapping screws. Attach the Access Point to the mounting plate (Figure 2).
Page 2
Step 3b (Any manufacturer’s access points) Install
the provided “T-Bar” bracket by fastening two (2) #8-32
self tapping screws into the enclosure mounting plate.
Attach the access point to the T-Bar bracket using the
manufacturer’s instructions for attaching the access
point to a ceiling tile grid (T-Bar). (Figure 3).
Step 4 (Optional) With the desired number of knockouts opened, attach
antennas (such as Oberon’s BMANT or DMDUAL) and DAS antennas by
inserting the cables through the door knockouts. Fasten the antennas to the
door per the antenna manufacturer’s instructions. To retain the water and
dust resistance of the enclosure, antennas should have a gasket to fill the
opening. After installation, connect the RF coax cable from the antenna to
the access point (Figure 4). If using Bulkhead connectors, use Oberon
Bulkhead connectors with provided o-ring (P/N 35-NFBLKHD) to maintain
water tightness.
The assembled unit is now ready for ceiling or wall installation.
Page 3
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Installation Instructions

Installation Instructions Model Number 1058-08-ANT5-F (877) 867-2312 • www.oberonwireless.com Rev. A1 05/23/13 Oberon, Inc. •••• 1315 South All

Page 2 - MODEL 1058-08-ANT5-F

Figure 8 – Tighten cable clamp around foam fire block so that there are no air gaps. Be careful not to over tighten and crush the Ethernet cable(s).

Commentaires sur ces manuels

Pas de commentaire